  1. Electrical quality and safety regs.

    Category: Electrical regulations

    ... or his equipment is a reference to a network, an overhead line, a substation or equipment (as the case may be) owned or operated by him. (7) Words and expressions to which meanings are assigned by these ...
    Tuesday, 11 August 2009
  2. Designing for the 17th

    Category: Regulations

    ... a rated current not exceeding 20A that are for use by 'ordinary persons' and are intended for general use are to be so protected. The definition of an 'ordinary person' is given above but, however ...
    Monday, 02 March 2009
  3. RCD's and the 17th

    Category: Regulations

    ...  Socket outlets with a rated current not exceeding 20A for use for general purposes by ordinary persons, and mobile equipment with a current rating not exceeding 32A for use outdoors are, to be ...
    Monday, 02 March 2009
  4. 17th Edition

    Category: Regulations

    ... provides guidance on how RCDs should be incorporated in new builds. One example is the requirement for cables concealed in a wall/partition at a depth of less than 50mm in domestic installations. ...
    Monday, 02 March 2009
  5. Electrical quality and safety regs.

    Category: Electrical/Regulations

    ... or his equipment is a reference to a network, an overhead line, a substation or equipment (as the case may be) owned or operated by him. (7) Words and expressions to which meanings are assigned by these ...
    Tuesday, 11 August 2009
  6. Designing for the 17th

    Category: Electrical/Regulations

    ... premises be protected by a 30mA RCD - not only those which may supply portable equipment for use outdoors. The wording is that socket-outlets with a rated current not exceeding 20A that are for use ...
    Monday, 02 March 2009
  7. RCD's and the 17th

    Category: Electrical/Regulations

    ... a rated current not exceeding 20A for use for general purposes by ordinary persons, and mobile equipment with a current rating not exceeding 32A for use outdoors are, to be protected by an RCD complying ...
    Monday, 02 March 2009
  8. 17th Edition

    Category: Electrical/Regulations

    ... provides guidance on how RCDs should be incorporated in new builds. One example is the requirement for cables concealed in a wall/partition at a depth of less than 50mm in domestic installations. Such ...
    Monday, 02 March 2009
  9. Galvanic table

    Category: Electrical/Regulations

    ... can be tolerated. Caution should be maintained when deciding for this application as humidity and temperature do vary from regions. Anodic Index Metallurgy   Index (V) Gold, solid ...
    Monday, 02 March 2009
  10. BT telecom circuits

    Category: Electrical/Regulations

    ...  in the newly decorated wall and only 2 wires have continuity - what do I do?? This is about the only occasion where you cheat and use a second master socket. The second master gives you back ...
    Sunday, 01 March 2009
  11. SWA as CPC?

    Category: Electrical/Regulations

    ... internal use and alternative exterior glands rated at IP66 for external use. The manufacturer’s gland kits are provided with suitably sized earth rings which are commonly known as “Banjos”. These ...
    Sunday, 01 March 2009
  12. Electricity at work act

    Category: Electrical/Regulations

    ... to be operated in case of danger. Oil-filled equipment 23. Electrical equipment using oil as a means of cooling, insulation or arc suppression shall not be introduced below ground at a mine. ...
    Sunday, 01 March 2009
  13. Electrical services and safety.

    Category: Electrical/News

    ... , ABS or the MCA. Our test instruments are tested and calibrated regularly. All our staff have professional qualifications. We are National Trust approved contractors. We regularly test to Part P and ...
    Tuesday, 30 November 1999