Search Keyword protected Total: 13 results found.

Search Result

  1. Electrical quality and safety regs.

    Category: Electrical regulations

    ... is - (a) sufficient for the purposes for and the circumstances in which it is used; and (b) so constructed, installed, protected (both electrically and mechanically), used and maintained as to prevent ...
    Tuesday, 11 August 2009
  2. Designing for the 17th

    Category: Regulations

    ...  Fig 1.Consumer unit - 2x30mA RCDs + 30mA RCBO. Fig 2. As Fig 1, but fire alarm MCB protected. Fig 3. As Fig 2 but alarm sysem not shown (not mains ...
    Monday, 02 March 2009
  3. RCD's and the 17th

    Category: Regulations

    ... protected by an RCD complying with Regulation 415.1.1, that is a device with a rated residual operating current not exceeding 30mA and an operating time not exceeding 40ms at five times the rated ...
    Monday, 02 March 2009
  4. 17th Edition

    Category: Regulations

    ... Such cables will need to be protected by an RCD rated at 30mA or below, even if they are in a safe zone. This has implications for lighting circuits, which - under the still current 16th Edition ...
    Monday, 02 March 2009
  5. Ring main Good / Bad?

    Category: News

    ... the devices connected to the ring to be appropriately protected on an individual basis. The standard fuses available are 13A, 5A & 3A, which covers the requirements of domestic devices from washing ...
    Sunday, 01 March 2009
  6. Electricity at work act

    Category: Electrical regulations

    ... environments 6. Electrical equipment which may reasonably foreseeably be exposed to-shall be of such construction or as necessary protected as to prevent, so far as is reasonably practicable, danger ...
    Sunday, 01 March 2009
  7. Electrical quality and safety regs.

    Category: Electrical/Regulations

    ... is - (a) sufficient for the purposes for and the circumstances in which it is used; and (b) so constructed, installed, protected (both electrically and mechanically), used and maintained as to prevent ...
    Tuesday, 11 August 2009
  8. Designing for the 17th

    Category: Electrical/Regulations

    ... unit - 2x30mA RCDs + 30mA RCBO. Fig 2. As Fig 1, but fire alarm MCB protected. Fig 3. As Fig 2 but alarm sysem not shown (not mains op.)  ...
    Monday, 02 March 2009
  9. RCD's and the 17th

    Category: Electrical/Regulations

    ... a rated current not exceeding 20A for use for general purposes by ordinary persons, and mobile equipment with a current rating not exceeding 32A for use outdoors are, to be protected by an RCD complying ...
    Monday, 02 March 2009
  10. 17th Edition

    Category: Electrical/Regulations

    ... cables will need to be protected by an RCD rated at 30mA or below, even if they are in a safe zone. This has implications for lighting circuits, which - under the still current 16th Edition - have ...
    Monday, 02 March 2009
  11. Ring main Good / Bad?

    Category: Electrical/News

    ... to the ring to be appropriately protected on an individual basis. The standard fuses available are 13A, 5A & 3A, which covers the requirements of domestic devices from washing machines to reading ...
    Sunday, 01 March 2009
  12. SWA as CPC?

    Category: Electrical/Regulations

    ... supplied premises and insulate the armouring at the remote end of the cable. This allows the SWA cable to be protected by the circuit protection device that is protecting the phase conductor(s) of ...
    Sunday, 01 March 2009
  13. Electricity at work act

    Category: Electrical/Regulations

    ... environments 6. Electrical equipment which may reasonably foreseeably be exposed to-shall be of such construction or as necessary protected as to prevent, so far as is reasonably practicable, danger ...
    Sunday, 01 March 2009