Designing for the 17th
Category: Regulations
... neither a skilled person nor an instructed person'. Socket-outlets circuits: Now we'll consider the requirements for socket-outlet circuits. Regulation 411.3.3 concerns additional protection, ...Monday, 02 March 2009 -
RCD's and the 17th
Category: Regulations
... of a particular item of equipment. Second: Section 701 Locations Containing a Bath or Shower. This has a requirement for additional protection of all circuits within these areas by one or more ...Monday, 02 March 2009 -
17th Edition
Category: Regulations
... Such cables will need to be protected by an RCD rated at 30mA or below, even if they are in a safe zone. This has implications for lighting circuits, which - under the still current 16th Edition ...Monday, 02 March 2009 -
Ring main Good / Bad?
Category: News
... outlets, which led to different circuits for the different outlets and a multiplicity of plugs and sockets. Oddly enough, that remains the current situation in Europe, but many countries that have ...Sunday, 01 March 2009 -
BT telecom circuits
Category: Regulations
Wiring for UK Telephone Sockets B - W = Blue with thin white bands W - B = White with thin blue bands O - W = Orange with thin white bands Colours ...Sunday, 01 March 2009 -
SWA as CPC?
Category: Regulations
... on single phase circuits. The cable is manufactured in both old and new harmonised colours for 3 phase. The use of this cable requires the over sleeving of cable cores to single phase colours and ...Sunday, 01 March 2009 -
Electricity at work act
Category: Electrical regulations
... and for isolation 12.—(1) Subject to paragraph (3), where necessary to prevent danger, suitable means (including, where appropriate, methods of identifying circuits) shall be available for- (2) In ...Sunday, 01 March 2009 -
Designing for the 17th
Category: Electrical/Regulations
... person'. Socket-outlets circuits: Now we'll consider the requirements for socket-outlet circuits. Regulation 411.3.3 concerns additional protection, and requires that all socket-outlets in domestic ...Monday, 02 March 2009 -
RCD's and the 17th
Category: Electrical/Regulations
... Second: Section 701 Locations Containing a Bath or Shower. This has a requirement for additional protection of all circuits within these areas by one or more RCDs with the previously mentioned characteristics. ...Monday, 02 March 2009 -
17th Edition
Category: Electrical/Regulations
... cables will need to be protected by an RCD rated at 30mA or below, even if they are in a safe zone. This has implications for lighting circuits, which - under the still current 16th Edition - have ...Monday, 02 March 2009 -
Ring main Good / Bad?
Category: Electrical/News
... different circuits for the different outlets and a multiplicity of plugs and sockets. Oddly enough, that remains the current situation in Europe, but many countries that have historic links with the ...Sunday, 01 March 2009 -
BT telecom circuits
Category: Electrical/Regulations
Wiring for UK Telephone Sockets B - W = Blue with thin white bands W - B = White with thin blue bands O - W = Orange with thin white bands Colours shown in brackets ...Sunday, 01 March 2009 -
SWA as CPC?
Category: Electrical/Regulations
... core cable on single phase circuits. The cable is manufactured in both old and new harmonised colours for 3 phase. The use of this cable requires the over sleeving of cable cores to single phase ...Sunday, 01 March 2009 -
Electricity at work act
Category: Electrical/Regulations
... and for isolation 12.—(1) Subject to paragraph (3), where necessary to prevent danger, suitable means (including, where appropriate, methods of identifying circuits) shall be available for- (2) In ...Sunday, 01 March 2009